About the company
 
Gal-Al Beverages Ltd. is one of the world's leaders in original developments of water technology, manufacturing and marketing.
Gal Al bears the ISO 9001-2000 international standard mark for marketing, service and installation.
Hardless products are manufactured in Israel in a plant in Haifa Bay that manufactures thousands of devices for markets throughout the world.
The company's products excel in original technologies that have been developed by Gal Al's personnel and that meet the strictest standards.
Gal Al products are successfully distributed throughout most of the world with the help of local distributors.
Gal Al has tens of thousands of customers, starting from private ones, institutes, organizations and defense systems.
Gal Al is involved in many projects and collaborations around the world, both in consultation and in building smart systems.  
The company is appreciated by water experts because of its development of original technologies, which has led competitors to try to spy on it by planting a Trojan horse in its development computers for information theft purposes.   
       
 Gal Al's personnel
 
Gal Al's people are handpicked based on standards of professionalism and human relations, go through workshops, training sessions and bonding days throughout the year and work in a "self-responsibility" environment without worker-manager relations.
The departments in Gal Al are examined and approved by the Standards Institute of Israel.
There are four major departments:
Development department – original, bright development people who can cope with every type of practical problem and who are bond enough to write chapters in "water philosophy", including the "outrageous" assumption of the presence of a fourth state of aggregation of water. The development department has an advanced research laboratory with advanced equipment.
Manufacturing department – professional, caring people with a "quality control" department for final testing.
Service department – has service personnel who devote their hearts and souls, controlled and managed by a service manager
and possessing a sophisticated repair laboratory for providing service with nationwide coverage.
Marketing department – the marketing people are experts in the field of water, their aim being providing a solution and consultation rather than necessarily sales.
 
Credo
 
Gal Al believes that tap water is of excellent quantity, exceeding that of mineral water and water purifiers.
Gal Al provides solutions of convenient, esthetics and saving of money by preventing limescale damage and water clearness.
Gal Al stands up against water companies that try to downplay the quality of tap water to promote economic interests.
Gal Al stands up against water companies that photograph infants next to their products to mislead the consumer that their water is suitable for infants without any need for boiling.
Gal Al stands up against water companies that do not tell the whole truth about their products.
Gal Al stands up against water companies that sell agricultural products that are unsuitable for human consumption
such as drink filtering products.
Gal Al stands up against water companies that associate their products with health.
 
2.1.3 Instructions folder for the Hardless
2.1.3.1 Installation instructions
 
The Hardless System includes the inlet/outlet connections of the (BSPT)"1, therefore should be verified the diameter of the piping and of the connectors designed for the installation of the Hardless; in the event that the diameter does not fit, should be obtained the appropriate connectors. The direction of the water flow in the apparatus is very important; the system should be installed according to the direction of the arrows shown on the product. In the event that the system is installed outdoors, it should be done after the municipality’s water meter.
Disconnect the water supply faucet, and then select the appropriate place for the installation of the Hardless; minimum of installation key: 16.6 cm.
If the installation height span is less than 20 cm, it is possible to install the Hardless in any desired angle.
In outdoors installation, the system’s outlet should be installed in the water pipe that conduits the water to the house.
In the event of indoors installation: install a pouring tap over the basin; the tap should be installed on the marble surface at a convenient distance from the basin. Drill on the marble with the appropriate 13 mm driller and connect the Hardless’ outlet to the pouring tap. Wrap the connectors with Teflon or linen tape in order to fortify the connection. Verify that the drainage tap is turned off. Open the supply tap and verify that is sealed; in the event of leakage, fortify the connection until the leakage stops.
 
Important!
 
-         In any case that the Ministry of Health or any other competent authority announces about a health hazard, you should behave according to the instructions including to boil the water.
-         In outdoor installations where exists an earth connection, the earth connection should be securely connected by-passing the Hardless system. The Hardless system is not conductive, therefore should be installed the propitious grounding connection.
-         In indoor installations under the sink, it is possible to connect the Hardless’ drainage to the trap (siphon) located under the sink. In this case, should be used an appropriate and standardized alternating current.
-         The Hardless should not be installed before the municipality’s water meter, but behind it.
-         In places where is likely to find leaks or fluids, it is recommended to dismantle the drainage tap and to set the plug supplied in the package ("3/4 bspt), or to order a protection box from the supplier.
-           When the system is installed far away (second floor and up), it is recommended to an alternating current or a tap at the Hardless outlet, and to prevent the waste of the water imprisoned in the piping up to the house.
-         The installation of the Hardless is appropriate only for places in which the quality of the drinking water is known and controlled.
 
 
 
 
 
 
 
 
 
 

Technical specification and requirements
 
-         Diameter of the inlet/outlet : 1” (bspt)          - Installation and/or maintenance
of the system to be executed by   the client or by the company for payment
-         System’s height> 26.6 cm                           - Working pressure: 1-6 bar
      -     Installation key 16.6 cm                                - Working temperature range: 1-  
                                                                                    50°C
      - Filtration level: stainless filter 49.9 micron    - Capacity in 1.5 Bar pressure:
      - Siliphos content: 330 gr.                                      5,000 liter/hour
 
 
 
 
                                        WWW.GAL-AL.CO.IL 
                       
 
 
2.1.3.2 Maintenance instructions
 
-         Once a month, the drainage tap should be rotated (in the lower part of the system) during 5 seconds.
-         Once a year, or 200 cubic meters, the supply tap should be turned off, and opened the drainage tap in order to release the pressure; open the lower part of the system (the filter’s container) and pull out the stainless filter. In the upper and/or lower part of the filter there is a border that should be removed for treatment. The filtering grid should be checked and cleaned as required, it is recommended to clean it in the dishwasher after removing the existing סיליפוס.
-         After finalizing the cleaning process, should be completed the missing סיליפוס.
-         After returning the stainless filter to its place -the direction is irrelevant- close well the filter container.
-         The drainage tap should be turned off, open the supply tap and inspect for leaks. If there is a leakage, fasten well until the leak stops.
 
Important
 
-         Areas where the level of non solute polluters (meaning particles) is high: repeat the drainage operation more frequently, and according to the level of pollutants in the region.
-         In areas with high level of scale, with unusual level of fur formation, the level of סיליפוס should be inspected every 6 months.
-         The Hardless should not be opened prior to the release of pressure, done by opening the drainage tap.
 
2.1.3.11 Warning instructions
-         In any case that the Ministry of Health or any other competent authority announces about a health hazard, you should behave according to the instructions including to boil the water.
-         The content of the filling (סיליפוס) must be produce of B.K Giulini – Germany.
 
Gal-Al Drinking Products Ltd.
 
 
 
               
                  
 
 

                            WWW.GAL-AL.CO.IL

 

         

 

  
                                                                        
אבנית
אבנית במים
אוסמוזה הפוכה
הסרת אבנית
טיהור מים
מטהר מים
מניעת אבנית
מסיר אבנית
מסנן אבנית
מסנן מים
מסנני מים
מערכות סינון
סינון אבנית
פילטר אבנית
פילטר מים
תמי 4
מים מטוהרים
 
                         דירות למכירה      
קייטרינג    משלוחי פרחים                                                                                                       

Webuildit - בניית אתר